Files
probe-basic-sim/configs/atc_sim/macros_sim/probe_back_top_side.ngc
2025-12-14 18:29:18 +01:00

92 lines
2.6 KiB
Plaintext

(author: Chris P)
(version: 0.4)
(date: 06/27/24)
(Probe back top side for y,z 0,0 position)
(Start probe position is over back edge of stock)
(inside the step off width distance and within max z distance)
(ensure all settings have been set properly according to help diagrams)
o<Probe_back_top_side> sub
(uses NGCGUI style arg spec)
(number after "=" in comment is default value)
#<probe_tool_number> = #3014 (=99)
#<probe_slow_fr> = #3015 (=0)
#<probe_fast_fr> = #3016 (=10.0)
#<probe_traverse_fr> = #3017 (=50)
#<max_xy_distance> = #3018 (=0.5000)
#<xy_clearance> = #3019 (=0.1000)
#<max_z_distance> = #3020 (=0.5000)
#<z_clearance> = #3021 (=0.1000)
#<extra_probe_depth> = #3022 (=0.0000)
#<step_off_width> = #3023 (=0.5000)
#<probe_mode> = #3030 (=0)
#<calibration_offset> = #3032 (=0)
(Cancel G92 offsets)
G92.1
(Cancel Feedrate Override)
M50 P0
#<workspace_y> = #[5202 + [20 * #5220]]
(Probe Tool Safety Check)
o100 if [#5400 NE #<probe_tool_number>]
(DEBUG, Specified probe tool %d#<probe_tool_number> not in spindle, aborting)
M50 P1
o<Probe_back_top_side> return
o100 endif
(Probe Diameter)
#<probe_diameter> = #5410
(Probing depth from the z probed clearance height, used for z moves)
#<z_probe_stack> = [#<z_clearance> + #<probe_diameter> + #<extra_probe_depth>]
(Call sub "probe_z_minus_sub" to Probe top of Workpiece)
o<probe_z_minus_sub> call [#3014][#3015][#3016][#3017][#3020][#3021][#3030]
(Probe Y Positioning Move, Step Off Width)
G91
F[#<probe_traverse_fr>]
G38.3 Y[#<step_off_width>]
(Probe Y Positioning Move, to Probing Depth)
F[#<probe_fast_fr>]
G38.3 Z-[#<z_probe_stack>]
(Call sub "probe_y_minus" to Probe y- side of Workpiece)
o<probe_y_minus> call [#3014][#3015][#3016][#3017][#3018][#3019][#3032]
#<y_minus_zero_edge> = #<_value>
(value returned safety check, aborts if no value returned)
o110 if [#<probe_mode> EQ 1 AND #<_value_returned> NE 1]
(DEBUG, Missing Y Sub returned edge parameter, aborting)
M50 P1
o<probe_back_top_side> return
o110 endif
(Probe Completion Move to Z Clearance Plane, and Y Zero)
G91
F[#<probe_traverse_fr>]
G38.3 Z[#<z_probe_stack>]
G90
F[#<probe_traverse_fr>]
G38.3 Y[#<y_minus_zero_edge>]
(probe mode rules for WCO or probe position measuring only)
o120 if [#<probe_mode> EQ 0]
(Record Zero in selected axes and WCO)
G10 L2 P#5220 Y[#<y_minus_zero_edge> + #<workspace_y>]
o120 endif
(Reinstate Feedrate Override)
M50 P1
o<Probe_back_top_side> endsub
M2 (end program)