# Configuration file for mb2hal to communicate with Vevor D100 VFD
|
|
# via Modbus RTU (RS485)
|
|
#
|
|
# Load component using:
|
|
# loadusr -W mb2hal config=vfd_d100.ini
|
|
|
|
[MB2HAL_INIT]
|
|
|
|
# Debug level: 0 = silent, 1 = errors, 2 = OK messages, 3 = debugging, 4 = max debug
|
|
INIT_DEBUG=1
|
|
|
|
# Set to 1.1 to enable float/int pin options and specific features
|
|
VERSION=1.1
|
|
|
|
# HAL module (component) name. Pins will be prefixed with this name.
|
|
HAL_MODULE_NAME=vfd
|
|
|
|
# Delay between transactions in seconds (helps slower VFDs process requests)
|
|
SLOWDOWN=0.1
|
|
|
|
# Number of transactions defined below
|
|
TOTAL_TRANSACTIONS=4
|
|
|
|
|
|
# =====================================================================
|
|
# TRANSACTION 00: Write Main Control Register (0200H / 512 dec)
|
|
# =====================================================================
|
|
[TRANSACTION_00]
|
|
LINK_TYPE=serial
|
|
SERIAL_PORT=/dev/ttyUSB0
|
|
SERIAL_BAUD=9600
|
|
SERIAL_BITS=8
|
|
SERIAL_PARITY=none
|
|
SERIAL_STOP=1
|
|
# Delay after transmission in ms (helps with VFD response processing and EMI)
|
|
SERIAL_DELAY_MS=50
|
|
MB_SLAVE_ID=1
|
|
|
|
MB_TX_CODE=fnct_06_write_single_register
|
|
FIRST_ELEMENT=512
|
|
NELEMENTS=1
|
|
HAL_TX_NAME=control
|
|
MAX_UPDATE_RATE=2.0
|
|
MB_RESPONSE_TIMEOUT_MS=1000
|
|
MB_BYTE_TIMEOUT_MS=1000
|
|
DEBUG=1
|
|
|
|
|
|
# =====================================================================
|
|
# TRANSACTION 01: Write Given Frequency (0201H / 513 dec)
|
|
# =====================================================================
|
|
[TRANSACTION_01]
|
|
MB_SLAVE_ID=1
|
|
MB_TX_CODE=fnct_06_write_single_register
|
|
FIRST_ELEMENT=513
|
|
NELEMENTS=1
|
|
HAL_TX_NAME=speed
|
|
MAX_UPDATE_RATE=2.0
|
|
MB_RESPONSE_TIMEOUT_MS=1000
|
|
MB_BYTE_TIMEOUT_MS=1000
|
|
DEBUG=1
|
|
|
|
|
|
# =====================================================================
|
|
# TRANSACTION 02: Read Main Control Status (0210H / 528 dec)
|
|
# =====================================================================
|
|
[TRANSACTION_02]
|
|
MB_SLAVE_ID=1
|
|
MB_TX_CODE=fnct_03_read_holding_registers
|
|
FIRST_ELEMENT=528
|
|
NELEMENTS=1
|
|
HAL_TX_NAME=status
|
|
MAX_UPDATE_RATE=2.0
|
|
MB_RESPONSE_TIMEOUT_MS=1000
|
|
MB_BYTE_TIMEOUT_MS=1000
|
|
DEBUG=1
|
|
|
|
|
|
# =====================================================================
|
|
# TRANSACTION 03: Read Operating Parameters (0220H - 0223H / 544 - 547 dec)
|
|
# =====================================================================
|
|
[TRANSACTION_03]
|
|
MB_SLAVE_ID=1
|
|
MB_TX_CODE=fnct_03_read_holding_registers
|
|
FIRST_ELEMENT=544
|
|
# Receptors:
|
|
# 544 (0220H) = Output Frequency (Hz * 10)
|
|
# 545 (0221H) = Set Frequency (Hz * 10)
|
|
# 546 (0222H) = Output Current (A * 10)
|
|
# 547 (0223H) = Output Speed (RPM)
|
|
PIN_NAMES=freq_out,freq_set,current,rpm
|
|
HAL_TX_NAME=metrics
|
|
MAX_UPDATE_RATE=2.0
|
|
MB_RESPONSE_TIMEOUT_MS=1000
|
|
MB_BYTE_TIMEOUT_MS=1000
|
|
DEBUG=1
|